ISO35 - Isolated 3.3-V Full-Duplex RS-485 Transceivers

Updated : 2020-01-09 14:32:05
Description

The ISO15 is an isolated half-duplex differential line transceiver while the ISO35 is an isolated full-duplex differential line driver and receiver for TIA/EIA 485/422 applications. The ISO15M and ISO35M have extended ambient temperature ratings of –55°C to 125°C while the ISO15 and ISO35 are specified over –40°C to 85°C.

These devices are ideal for long transmission lines because the ground loop is broken to allow for a much larger common-mode voltage range. The symmetrical barrier of the device is tested to provide isolatlion of 4000 VPK per VDE and 2500 VRMS per UL and CSA between the bus-line transceiver and the logic-level interface.

Any cabled I/O can be subjected to electrical noise transients from various sources. These noise transients can cause damage to the transceiver and/or nearby sensitive circuitry if they are of sufficient magnitude and duration. These isolated devices can significantly increase protection and reduce the risk of damage to expensive control circuits.

Products containing the "ISO35" keyword are: ISO35 , ISO35DW , ISO35DW , ISO35DWG4 , ISO35DWG4 , ISO35DWR , ISO35DWR , ISO35DWRG4 , ISO35MDW , ISO35MDW , ISO35MDWR , ISO35MDWR , ISO35TDW , ISO35TDW , ISO35TDWR , ISO35TDWR , ISO35TEVM , ISO35TEVM , ISO35TEVM-434 , ISO35TEVM-434
Features

  • Meets or Exceeds TIA/EIA RS-485 Requirements
  • 1/8 Unit Load – Up to 256 Nodes on a Bus
  • Signaling Rates up to 1 Mbps
  • Thermal Shutdown Protection
  • Low Bus Capacitance – 16 pF (Typical)
  • 50 kV/µs Typical Transient Immunity
  • Fail-safe Receiver for Bus Open, Short, Idle
  • 3.3-V Inputs are 5-V Tolerant
  • Safety and Regulatory Approvals
    • 4000-VPK VIOTM, 560-VPK VIORM per DIN V VDE
      V 0884-10 (VDE V 0884-10):2006-12 and DIN EN 61010-1
    • 2500 VRMS Isolation Rating per UL 1577
    • 2500 VRMS Isolation Rating per CSA CA5A and IEC 60950-1
  • APPLICATIONS
    • Security Systems
    • Chemical Production
    • Factory Automation
    • Motor and Motion Control
    • HVAC and Building Automation Networks
    • Networked Security Stations

All other trademarks are the property of their respective owners

Parametrics
StatusACTIVE
SubFamilyIsolated RS-485 transceivers
Isolation rating2500
Surge Voltage Rating4000
DIN V VDE V 0884-10 transient overvoltage rating4000
DIN V VDE V 0884-10 working voltage560
CSA 60950-1 basic working280
CSA 60950-1 reinforced working
CSA 61010-1 basic workingN/A
CSA 61010-1 reinforced workingN/A
CSA 60601-1 reinforced working
CSA isolation rating2500
TUV EN 60950-1 Basic Working
TUV EN 60950-1 Reinforced Working
TUV EN 61010-1 Basic Working
TUV EN 61010-1 Reinforced Working
TUV Isolation Rating
Operating temperature range-40 to 85
Package GroupSOIC|16
Package size: mm2:W x L (PKG)[pf]16SOIC[/pf]: 106 mm2: 10.3 x 10.3 (SOIC|16)
Approx. price3.00 | 1ku
RatingCatalog