ISO1500 - 3-kVRMS basic isolated RS-485/RS-422 transceiver in ultra-small package

Updated : 2020-01-09 14:32:03
Description

The ISO1500 device is a galvanically-isolated differential line transceiver for TIA/EIARS-485 and RS-422 applications. This device has a 3-channel digital isolator and an RS-485transceiver in an ultra-small 16-pin SSOP package. The bus pins of this transceiver are protectedagainst IEC ESD contact discharge and IEC EFT events. The receiver output has a failsafe for busopen, short, and idle conditions. The small solution size of ISO1500 greatly reduces the boardspace required compared to other integrated isolated RS-485 solutions or discrete implementationwith optocouplers and non-isolated RS-485 transceiver.

The device is used for long distance communications. Isolation breaks the ground loopbetween the communicating nodes, allowing for a much larger common mode voltage range. Thesymmetrical isolation barrier of each device is tested to provide 3000 VRMSof isolation for 1 minute per UL 1577 between the bus-line transceiver and the logic-levelinterface.

The ISO1500 device can operate from 1.71 V to 5.5 V on side 1 which lets the devicesinterface with low-voltage FPGAs and ASICs. The supply voltage on side 2 is from 4.5 V to 5.5 V.This device supports a wide operating ambient temperature range from –40°C to +125°C.

Products containing the "ISO1500" keyword are: ISO1500DBQ , ISO1500DBQEVM , ISO1500DBQR
Features

  • Meets or Exceeds Requirements of TIA/EIA-485-A
  • Half-Duplex Transceiver
  • Low-EMI 1-Mbps Data Rate
  • 1.71-V to 5.5-V Logic-Side Supply (VCC1), 4.5-V to 5.5-V Bus-Side Supply (VCC2)
  • 1/8 Unit Load: Up to 256 Nodes On Bus
  • Failsafe Receiver For Bus Open, Short, and Idle
  • 100-kV/µs (typical) High Common-Mode Transient Immunity
  • Extended Temperature Range from –40°C to +125°C
  • Glitch-Free Power-Up and Power-Down for Hot Plug-In
  • Ultra-Small SSOP (DBQ-16) Package
  • Safety-Related Certifications:
    • All Certifications Planned
    • 4242-VPK VIOTM and 566-VPK VIORM per DIN V VDE V 0884-11:2017-01
    • 3000-VRMS Isolation for 1 Minute per UL 1577
    • IEC 60950, IEC 60601 and EN 61010 Certifications
    • CQC, TUV, and CSA Certifications

All trademarks are the property of their respective owners.

Parametrics
StatusPREVIEW
SubFamilyIsolated RS-485 transceivers
Isolation rating2500
Surge Voltage Rating4000
DIN V VDE V 0884-10 transient overvoltage rating4242
DIN V VDE V 0884-10 working voltage566
CSA 60950-1 basic working370
CSA 60950-1 reinforced working
CSA 61010-1 basic working
CSA 61010-1 reinforced working300
CSA 60601-1 reinforced working
CSA isolation rating3000
TUV EN 60950-1 Basic Working
TUV EN 60950-1 Reinforced Working
TUV EN 61010-1 Basic Working
TUV EN 61010-1 Reinforced Working
TUV Isolation Rating
Operating temperature range-40 to 125
Package GroupSSOP|16
Package size: mm2:W x L (PKG)[pf]16SSOP[/pf]: 29 mm2: 6 x 4.9 (SSOP|16)
Approx. price2.15 | 1ku
RatingCatalog