The LMx39x and the LM2901x devices consist of four independent voltage comparators thatare designed to operate from a single power supply over a wide range of voltages. Operation fromdual supplies also is possible, as long as the difference between the two supplies is 2 V to 36 V,and VCC is at least 1.5 V more positive than the input common-mode voltage.Current drain is independent of the supply voltage. The outputs can be connected to otheropen-collector outputs to achieve wired-AND relationships.
The LM139 and LM139A devices are characterized for operation over the full militarytemperature range of –55°C to +125°C. The LM239 and LM239A devices are characterized for operationfrom –25°C to +85°C. The LM339 and LM339A devices arecharacterized for operation from 0°C to 70°C. The LM2901, LM2901AV, and LM2901V devices arecharacterized for operation from –40°C to +125°C.
Products containing the "LM339" keyword are: LM339 , LM339-SR , LM339. , LM339/36V , LM339/S339 , LM339/SOP-14/DIP-14 , LM339/TS339 , LM3390 , LM3390G , LM339A , LM339AD , LM339AD , LM339AD/MOTOROLA , LM339AD3 , LM339ADBR , LM339ADBR , LM339ADBR /L339A , LM339ADBRG4 , LM339ADBRG4 , LM339ADE4All trademarks are the property of their respective owners.
Status | ACTIVE |
SubFamily | Comparators |
Number of channels | 4 |
Output type | Open Collector |
Propagation delay time | 0.3 |
Vs | 2 |
Package Group | PDIP|14 |
Vos (offset voltage @ 25 C) | 5 |
Iq per channel | 0.2 |
Input bias current (+/-) | 50 |
Rail-to-rail | Out |
Rating | Catalog |
Operating temperature range | 0 to 70 |
Package size: mm2:W x L (PKG) | See datasheet (PDIP) |
Approx. price | 0.07 | 1ku |
Features | N/A |
VICR | 0 |